| Availability: | |
|---|---|
NKS-15/200-BW
NKS POWER
636CPS-SZ
The NKS Power 200A Load Break Elbow Connector is a high-performance electrical connection designed specifically for 15kV power systems. It is suitable for connecting underground cables rated at 200A to transformers, switchgear, and other equipment equipped with 200A load-break bushings. This product complies with ANSI/IEEE standards and is compatible with Type A bushings in EN50180 and 50181.
Product execution standard: IEEE 38
1. Excellent Insulation
Molded from safe and environmentally friendly silicone rubber, it offers excellent insulation, corona, and tracking resistance.
2. Advanced Structural Design
A rational structural design and a three-layer post-injection peroxide cross-linking process effectively reduce partial discharge.
3. Built-in Stress Control
A built-in stress control device ensures uniform electric field distribution.
4. Test Point
Equipped with a test point, it can be equipped with a live display or fault indicator to display the operating status of the equipment.
5. Stainless Steel Pull Ring
Equipped with a stainless steel pull ring and anti-loosening device, it ensures a stable connection.
6. Wide Applicability
Suitable for copper and aluminum cables with a cross-sectional area ranging from 25 to 120 mm².
NKS-15/200-BW | Items | Parameter |
| Technical Parameters | System Voltage | 15kV |
Rated current | 200A | |
Frequency withstand voltage(AC) | 42kV/5min | |
Partial Discharge | 15kV<5pC | |
Impulse voltage | 95kV |
The NKS Power 200A Load Break Elbow Connector is a high-performance electrical connection designed specifically for 15kV power systems. It is suitable for connecting underground cables rated at 200A to transformers, switchgear, and other equipment equipped with 200A load-break bushings. This product complies with ANSI/IEEE standards and is compatible with Type A bushings in EN50180 and 50181.
Product execution standard: IEEE 38
1. Excellent Insulation
Molded from safe and environmentally friendly silicone rubber, it offers excellent insulation, corona, and tracking resistance.
2. Advanced Structural Design
A rational structural design and a three-layer post-injection peroxide cross-linking process effectively reduce partial discharge.
3. Built-in Stress Control
A built-in stress control device ensures uniform electric field distribution.
4. Test Point
Equipped with a test point, it can be equipped with a live display or fault indicator to display the operating status of the equipment.
5. Stainless Steel Pull Ring
Equipped with a stainless steel pull ring and anti-loosening device, it ensures a stable connection.
6. Wide Applicability
Suitable for copper and aluminum cables with a cross-sectional area ranging from 25 to 120 mm².
NKS-15/200-BW | Items | Parameter |
| Technical Parameters | System Voltage | 15kV |
Rated current | 200A | |
Frequency withstand voltage(AC) | 42kV/5min | |
Partial Discharge | 15kV<5pC | |
Impulse voltage | 95kV |