| Availability: | |
|---|---|
NKS-15kVYZI- NKS-15kVYZO-
NKS POWER
Pre-molded power cable terminations are inlaid with stress control parts in the insulation body in advance in the factory production, no interface exists, through the stress control parts to effectively solve the problem of stress concentration at the cable shield cut. Using silicon rubber high resilience, high temperature resistance and strong aging resistance, and cable insulation to adopt interference combined design. This ensures that the interface between cable insulation and accessories is closely combined without internal creepage. In order to meet the four types of pollution environment, and design the external insulation of the accessories. 15kV prefabricated cold shrinkage power cable accessories are suitable for the connection of 6/10kV, 8. 7/15kV single/three core XLPE power cable.
Product execution standards: IEC60502.4, GB/T12706.4
This material gives very good electrical and mechanical properties, stable performance of the terminal under any aggressive environment. High elasticity, heat resistance material anti-aging characteristics extend the lifespan of the terminal thus reducing on maintenance costs.
Prefabricated power cable Terminations can resist high mechanical forces. They allow for variation accommodation between different types and sizes of cables, whether single-core or three-core, ensuring that there is always a firm connection between the termination and the cable which cannot work loose due to any mechanical vibration or outside force.
The material of the terminals effectively resists any UV degradation and can keep up its performance even if mounted outdoors in direct sunlight for very long hours. It also has great weather resistance, material can acclimate to any climatic condition from high and low temperature to humidity and aridity.
Prefabricated power cable terminations are made of a high-quality insulation material that can effectively prevent electrical leakage and short-circuit incidents. The special treatment applied to the insulation material results in high insulation resistance and low dielectric loss, thus safe and reliable operation of power transmission can be attained.
The terminal has been designed with anti-corona and anti-tracking features. With this feature, no corona discharge or even tracking formation will take place under any circumstances, even under high-voltage as well as high-humidity conditions; therefore, the service life of the terminal will not be shortened.
The terminal adopts a simple design and rational structure which makes installation and maintenance work easy. Due to its small size, it allows for proper electrical connections in confined spaces, hence applicable to different complex installation environments.
The terminal has built-in stress control components that function efficiently in managing the stresses that usually build up at the points of termination of cable shields. This product ensures an even distribution of the electric field so there is no partial discharge during operation that would reduce the quality and reliability of the product.
Prefabricated power cable terminals work with both copper and aluminum wires to meet the needs of different users. They offer strong connection options for new power setups and changes to old infrastructure.
The terminal design supports more than one connection, which includes crimping and mechanical clamping. The user may choose the connection type under particular conditions that will ensure a secure bond of the terminal with the cable.
Making ready pre-built power wire ends is straight and quick, needing no hard tools or gear. Their pre-made build form greatly cuts down on setup time and lowers costs. Also, care is very handy letting users check and swap out broken parts to keep things running.
Ⅲ. Electrical Performance Parameters of Pre-molded Power Cable Termination
NKS-15kVYZO(I)- | Items | Parameter |
Technical Parameters | Cable rated voltage | 6/10kV 8.7/15kV |
| Frequency withstand voltage(AC) | 39kV/5min | |
Partial Discharge | 15kV<10pC | |
Impulse voltage | 105kV | |
| Heating cycles test in air | 23kV, 60 cycles in total | |
Applicable cable cross section | 25-630mm² |
The product has passed the inspection and certification of the China Electric Power Research Institute (CEPRI) Power Industry Electrical Equipment Quality Inspection and Testing Center
Type test reference standard: IEC 60502-4:2010 GB/T 12706.4-2008
| Product name | Nominal cross section (mm²) | Kit Code(indoor) | Kit Code(outdoor) |
3-core Pre-molded termination | 50 | NKS-15kVYZI-3/1 | NKS-15kVYZO-3/1 |
| 70 | NKS-15kVYZI-3/2 | NKS-15kVYZO-3/2 | |
| 95 | NKS-15kVYZI-3/3 | NKS-15kVYZO-3/3 | |
| 120 | NKS-15kVYZI-3/4 | NKS-15kVYZO-3/4 | |
| 150 | NKS-15kVYZI-3/5 | NKS-15kVYZO-3/5 | |
| 185 | NKS-15kVYZI-3/6 | NKS-15kVYZO-3/6 | |
| 240 | NKS-15kVYZI-3/7 | NKS-15kVYZO-3/7 | |
| 300 | NKS-15kVYZI-3/8 | NKS-15kVYZO-3/8 | |
| 400 | NKS-15kVYZI-3/9 | NKS-15kVYZO-3/9 | |
| 500 | NKS-15kVYZI-3/10 | NKS-15kVYZO-3/10 | |
Single core Pre-molded termination | 50 | NKS-15kVYZI-1/1 | NKS-15kVYZO-1/1 |
| 70 | NKS-15kVYZI-1/2 | NKS-15kVYZO-1/2 | |
| 95 | NKS-15kVYZI-1/3 | NKS-15kVYZO-1/3 | |
| 120 | NKS-15kVYZI-1/4 | NKS-15kVYZO-1/4 | |
| 150 | NKS-15kVYZI-1/5 | NKS-15kVYZO-1/5 | |
| 185 | NKS-15kVYZI-1/6 | NKS-15kVYZO-1/6 | |
| 240 | NKS-15kVYZI-1/7 | NKS-15kVYZO-1/7 | |
| 300 | NKS-15kVYZI-1/8 | NKS-15kVYZO-1/8 | |
| 400 | NKS-15kVYZI-1/9 | NKS-15kVYZO-1/9 | |
| 500 | NKS-15kVYZI-1/10 | NKS-15kVYZO-1/10 |
Pre-molded power cable terminations are inlaid with stress control parts in the insulation body in advance in the factory production, no interface exists, through the stress control parts to effectively solve the problem of stress concentration at the cable shield cut. Using silicon rubber high resilience, high temperature resistance and strong aging resistance, and cable insulation to adopt interference combined design. This ensures that the interface between cable insulation and accessories is closely combined without internal creepage. In order to meet the four types of pollution environment, and design the external insulation of the accessories. 15kV prefabricated cold shrinkage power cable accessories are suitable for the connection of 6/10kV, 8. 7/15kV single/three core XLPE power cable.
Product execution standards: IEC60502.4, GB/T12706.4
This material gives very good electrical and mechanical properties, stable performance of the terminal under any aggressive environment. High elasticity, heat resistance material anti-aging characteristics extend the lifespan of the terminal thus reducing on maintenance costs.
Prefabricated power cable Terminations can resist high mechanical forces. They allow for variation accommodation between different types and sizes of cables, whether single-core or three-core, ensuring that there is always a firm connection between the termination and the cable which cannot work loose due to any mechanical vibration or outside force.
The material of the terminals effectively resists any UV degradation and can keep up its performance even if mounted outdoors in direct sunlight for very long hours. It also has great weather resistance, material can acclimate to any climatic condition from high and low temperature to humidity and aridity.
Prefabricated power cable terminations are made of a high-quality insulation material that can effectively prevent electrical leakage and short-circuit incidents. The special treatment applied to the insulation material results in high insulation resistance and low dielectric loss, thus safe and reliable operation of power transmission can be attained.
The terminal has been designed with anti-corona and anti-tracking features. With this feature, no corona discharge or even tracking formation will take place under any circumstances, even under high-voltage as well as high-humidity conditions; therefore, the service life of the terminal will not be shortened.
The terminal adopts a simple design and rational structure which makes installation and maintenance work easy. Due to its small size, it allows for proper electrical connections in confined spaces, hence applicable to different complex installation environments.
The terminal has built-in stress control components that function efficiently in managing the stresses that usually build up at the points of termination of cable shields. This product ensures an even distribution of the electric field so there is no partial discharge during operation that would reduce the quality and reliability of the product.
Prefabricated power cable terminals work with both copper and aluminum wires to meet the needs of different users. They offer strong connection options for new power setups and changes to old infrastructure.
The terminal design supports more than one connection, which includes crimping and mechanical clamping. The user may choose the connection type under particular conditions that will ensure a secure bond of the terminal with the cable.
Making ready pre-built power wire ends is straight and quick, needing no hard tools or gear. Their pre-made build form greatly cuts down on setup time and lowers costs. Also, care is very handy letting users check and swap out broken parts to keep things running.
Ⅲ. Electrical Performance Parameters of Pre-molded Power Cable Termination
NKS-15kVYZO(I)- | Items | Parameter |
Technical Parameters | Cable rated voltage | 6/10kV 8.7/15kV |
| Frequency withstand voltage(AC) | 39kV/5min | |
Partial Discharge | 15kV<10pC | |
Impulse voltage | 105kV | |
| Heating cycles test in air | 23kV, 60 cycles in total | |
Applicable cable cross section | 25-630mm² |
The product has passed the inspection and certification of the China Electric Power Research Institute (CEPRI) Power Industry Electrical Equipment Quality Inspection and Testing Center
Type test reference standard: IEC 60502-4:2010 GB/T 12706.4-2008
| Product name | Nominal cross section (mm²) | Kit Code(indoor) | Kit Code(outdoor) |
3-core Pre-molded termination | 50 | NKS-15kVYZI-3/1 | NKS-15kVYZO-3/1 |
| 70 | NKS-15kVYZI-3/2 | NKS-15kVYZO-3/2 | |
| 95 | NKS-15kVYZI-3/3 | NKS-15kVYZO-3/3 | |
| 120 | NKS-15kVYZI-3/4 | NKS-15kVYZO-3/4 | |
| 150 | NKS-15kVYZI-3/5 | NKS-15kVYZO-3/5 | |
| 185 | NKS-15kVYZI-3/6 | NKS-15kVYZO-3/6 | |
| 240 | NKS-15kVYZI-3/7 | NKS-15kVYZO-3/7 | |
| 300 | NKS-15kVYZI-3/8 | NKS-15kVYZO-3/8 | |
| 400 | NKS-15kVYZI-3/9 | NKS-15kVYZO-3/9 | |
| 500 | NKS-15kVYZI-3/10 | NKS-15kVYZO-3/10 | |
Single core Pre-molded termination | 50 | NKS-15kVYZI-1/1 | NKS-15kVYZO-1/1 |
| 70 | NKS-15kVYZI-1/2 | NKS-15kVYZO-1/2 | |
| 95 | NKS-15kVYZI-1/3 | NKS-15kVYZO-1/3 | |
| 120 | NKS-15kVYZI-1/4 | NKS-15kVYZO-1/4 | |
| 150 | NKS-15kVYZI-1/5 | NKS-15kVYZO-1/5 | |
| 185 | NKS-15kVYZI-1/6 | NKS-15kVYZO-1/6 | |
| 240 | NKS-15kVYZI-1/7 | NKS-15kVYZO-1/7 | |
| 300 | NKS-15kVYZI-1/8 | NKS-15kVYZO-1/8 | |
| 400 | NKS-15kVYZI-1/9 | NKS-15kVYZO-1/9 | |
| 500 | NKS-15kVYZI-1/10 | NKS-15kVYZO-1/10 |